MODEL 34
MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A ZERO
CLEARANCE FIREPLACE OR WITH AN OPTIONAL
SURROUND.
WAR N I N G: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is in-
stalled. Provisions for adequate combustion and ventilation air must be provided. Refer to
section “ Producing Adequate Ventilation” page 35.
This appliance may be installed in an aftermarket, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.
Manufacturer: NEW BUCK CORPORATION
P.O. Box 69
8000 Highway 226 South
Spruce Pine, NC 28777
This appliance is intended for supplemental heating.
Revised December 2006
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Seitenansicht 0
1 2 3 4 5 6 ... 54 55

Inhaltsverzeichnis

Seite 1 - SURROUND

MODEL 34 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL SURROUND. WAR N I N G: If the informat

Seite 2

CR3329 CERAMIC LOG SET PLACEMENT, FOR MODEL 34 (1-L) (2) (4) (3) WARNING: Failure to position the parts in accordance with these diagra

Seite 3 - TABLE OF CONTENTS MODEL 34

EMBER STOVE LOG SET PLACEMENT FOR MODEL 34 MODEL E.S.B: 1)Rear Log, 2)Middle Log, 3)Left Top Middle Log, 4)Right Top Middle Log 5)Left Fro

Seite 4

GAS PRESSURE CHECK Check the inlet pressure to the burner to ensure that it is as shown in the table below. NOTE: The pressure check point is located

Seite 5 - SECTION I

LIGHTING INSTRUCTIONS MILLIVOLT VALVE (ITT) FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE O

Seite 6

LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on previous page. 2. Make sure the manual shutoff valve is fully closed.If equipped wi

Seite 7

• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. TO TURN O

Seite 8 - FIREPLACE PREPARATION

THERMOSTAT CONTROL OPERATION • This valve operates off of millivolts produced by the generator. You may choose to use an optional Wall Thermostat o

Seite 9 - GAS CONNECTION

LIGHTING INSTRUCTION MODULATING VALVE (SIT) MANUAL VALVE (SIT) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW T

Seite 10

LIGHTING INSTRUCTION 1. STOP! Read the safety information on preceding page 15. 2. Make sure manual shutoff valve is fully closed. 3. Turn off a

Seite 11

11. Turn gas control knob counterclockwise to “ON” position. Continue to turn the gas control knob counterclockwise

Seite 13 - WARNING

THERMOSTAT CONTROL OPERATION 1. The thermostat control on this heater differs from standard thermostats. Standard thermostats simply turn the burne

Seite 14 - CONTROL KNOB

OPERATING INSTRUCTIONS Before operating this appliance, proceed through the following checklist. 1. Read and understand these instructions before o

Seite 15 - THERMO-PILE

REMOTE CONTROL OR WALL THERMOSTAT NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force. 6. Wait (5)

Seite 16 - THERMOSTAT CONTROL OPERATION

* If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 11. Turn c

Seite 17 - MANUAL VALVE (SIT)

MANUAL LIGHTING PROCEDURE 1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper match and a lighter rod. 2.

Seite 18

FLAME CHECK A periodic check of the flames should be made. The pilot flame should always be present when the gas logs are in operation. See Figure

Seite 19 - TO TURN OFF GAS TO APPLIANCE

WIRING DIAGRAM NOTE: “If any of the original wire as supplied with the gas appliance must be replaced, it must be replaced with a wire of at least a 1

Seite 20

WARNING: ELECTRICAL GROUNDING INSTRUCTION: THIS HEATER IS EQUIPPED WITH A THREE-PRONG PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLU

Seite 21 - SIT-MILLIVOLT VALVE

SECTION III INSTALLATION MODEL 34 (FP) IN SOLID FUEL BURNING FIREPLACES (1) The Model FP-34 may be installed in a masonry fireplace. The minimum fire

Seite 22

B. Set the top (long) trim panel in place on top of unit. The panel should be flat against the outside face of the fireplace, and standing vertical

Seite 23

TABLE OF CONTENTS MODEL 34 SECTION I: Safety Information... 3 SE

Seite 24

SECTION IV INSTALLATION OF MODEL 34 (WS) OPTIONAL WOODEN SURROUND (KIT#PAKDFP34) NOTE: See page 26, figure 6 for clearances. (1) When choosing the

Seite 25 - HEAT OUTPUT

STEP 7: Slide the unit into the front opening of the surround so the top metal trim panel and outer sides of the heater meet flush with the surround

Seite 26 - WIRING DIAGRAM

SECTION V MODEL 34 (ZC) ZERO CLEARANCE INSTALLATION The installation must conform with local codes ,or in the absence of local codes, with the

Seite 27

3-1/4"4-1/4"GAS LINE WARNING: Installation and repairs should be performed by a qualified service person. The appliance should be inspec

Seite 28 - INSTALLATION MODEL 34 (FP)

FIREPLACE CLEARANCES (ZC) The fireplace may be placed directly on a combustible floor, against a combustible wall at marked clear-ances, or on a rai

Seite 29

FINISHING YOUR FIREPLACE (ZC) There is a wide variety of finishing material available for your fireplace from formal wall treatments with marble and

Seite 30 - SECTION IV

SECTION VI AFTER MARKET MOBILE HOME INSTALLATION NOTE: See “Producing Adequate Ventilation” page 35 .THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMAR

Seite 31 - SURROUND BASE

PRODUCING ADEQUATE VENTILATION This section is for residential or manufactured (mobile) installation “This heater shall not be installed in a confine

Seite 32 - SECTION V

1. Determine the volume of the space (length x width x height). Length x Width x Height =_________cu.ft.(volume of space) EX

Seite 33 - GAS LINE

VENTILATION AIR VENTILATION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconfined space. When venting to an adjoining spa

Seite 35 - MATERIAL

VENTILATION AIR FROM OUTDOORS Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12&q

Seite 36 - INSTALLATION

IMPORTANT SAFEGUARDS Although your gas logs are very realistic in appearance, it is not a real burning fireplace and must not be used for burning rej

Seite 37 - HEATER LOCATION

TROUBLESHOOTING WARNING TURN OFF, UNPLUG HEATER AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR HEATER. CAU

Seite 38 - CONFINED SPACE

OBSERVED PROBLEM ODS/PILOT lights but flame goes out when control knob is released 4. Air in gas lines when installed 5. Depleted gas

Seite 39 - VENTILATION AIR

OBSERVED PROBLEM Burner does not light after ODS/Pilot is lit Delayed ignition of burner Burner backfiring during combustion Slight smok

Seite 40

WARNING IF YOU SMELL GAS: * SHUT OFF GAS SUPPLY * DO NOT TRY TO LIGHT APPLIANCE * DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY

Seite 41

SERVICING Repair and replacement work should only be performed by a qualified service technician. Always shut off the gas supply and make sure heate

Seite 42 - CAUTION

REPLACEMENT PARTS ITT VALVE (Picture on page 46) KEY# PART DESCRIPTION PART NUMBER 1. Carling Switch PE RA911VB 2. Female Terminals PE

Seite 43

ON123467892013171619125111415181021THERMOGENAUXPRESS TORESETOFFPILOTONITTGENERALCONTROLSPILOTADJ 46

Seite 44

REPLACEMENT PARTS SIT MODULATING OR MANUAL VALVE (Picture on page 48) KEY# PART DESCRIPTION PART NUMBER 1. Pilot (NAT.) Copreci PE 2150053

Seite 45

SECTION I SAFETY INFORMATION WARNINGS IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO A

Seite 46 - SERVICING

10PILOTOFFHILOSit9123A16183B475861213111217151419 48

Seite 47 - REPLACEMENT PARTS

REPLACEMENT PARTS SIT MILLIVOLT VALVE Picture on Page 50 KEY#

Seite 48

SIT MILLIVOLT 15 8 16 2 4 5 3 7 1 6 17 18 19 9 10 11 13 12 14 20 21 50

Seite 49

REPLACEMENT PARTS FOR EMBER STOVE BASE (ESB) (PICTURE ON PAGE 47) A parts list with exploded view follows. Always include correct name, part number,

Seite 50

52 10 6 11 13 8 7 16 16 5 1 14 2 3 4 6 17 15 12 REPAIR PARTS A parts list with exploded view follows. Always include correct name, part

Seite 51

NEW BUCK CORPORATION We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard wri

Seite 52 - SIT MILLIVOLT

5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure. 6. What To Do IF You Smell Gas: Shu

Seite 53 - EMBER STOVE BASE (ESB)

21. All heater screens must be kept closed when operating the gas logs. 22. ”WARNING: Failure to keep the primary air opening (s) of the burner (s)

Seite 54 - REPAIR PARTS

SECTION II FIREPLACE PREPARATION The fireplace needs to be prepared before installing the heater. A. Turn off the gas supply to the fireplace.

Seite 55 - NEW BUCK CORPORATION

INSTALLATION AND CLEARANCES To ensure a safe installation into a masonry or factory built fireplace, the following instructions must be carefully fol