MODEL 42 MAY BE INSTALLED AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND WARNING: If the information in this manual is not followe
FIREPLACE CLEARANCES (ZC) The fireplace may be placed directly on a combustible floor, against a combustible wall at marked clearances, or on a ra
FINISHING YOUR FIREPLACE (ZC) There is a wide variety of finishing material available for your fireplace from formal wall treatments with marble and m
MANTEL PROFILES FOR ZERO CLEARANCE (ZC) CABINET MUST BE FOLLOWED 3"50-3/8"2-3/8"2-3/8"FRONT VIEW OF MODEL 42-ZC-FPFLAT MANTEL WITH
INSTALLATION OF MODEL 42 (WS) WITH OPTIONAL WOODEN SURROUND (KIT#PAKDM42) 1. When choosing the right location for your heater and wooden surround (m
9. Now you are ready to position the log set. See pages 18, 19, 20. 10. To light the heater, see “Lighting Instructions”, pages 21 through 32. Make
PRODUCING ADEQUATE VENTILATION This section is for residential or manufactured (mobile) installation “This heater shall not be installed in a confine
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION DETERMINE IF YOU HAVE A CONFINED OR UNCONFINED SPACE Use this worksheet to determine if you have co
VENTILATION AIR VENTILATION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconfined space. When venting to an adjoining space
VENTILATION AIR FROM OUTDOORS Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12&q
WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS. GAS CONNECTION Check gas type. Use only the type of gas indicated on the valv
PLACEMENT OF LOGS FOR FP-42-ZC DX 2733 Open the carton containing the logs. The logs are boxed separated: WARNING: POSITIONING OF LOGS IS VERY
NOTE: When operated for the first time, logs may emit a “paper burning” smell. This smell will gradually diminish and will be totally eliminated af
EMBER STOVE LOG SET PLACEMENT FOR MODEL 42 MODEL E.S.B: 1)Rear Log, 2)Middle Log, 3)Left Top Middle Log, 4)Right Top Middle Log 5)Left Fron
CR3329 CERAMIC LOG SET PLACEMENT FOR MODEL 42 (1) (2) (4) (3) WARNING: Failure to position the parts in accordance with these diagra
LIGHTING INSTRUCTIONS MILLIVOLT VALVE (ITT) FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE O
LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on previous page. 2. Make sure the manual shutoff valve is fully closed. If equipped w
• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. TO TURN O
THERMOSTAT CONTROL OPERATION • This valve operates off of millivolts produced by the generator. You may choose to use an optional Wall Thermostat o
LIGHTING INSTRUCTION MODULATING VALVE (SIT) OR MANUAL VALVE (SIT) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLO
LIGHTING INSTRUCTION 1. STOP! Read the safety information on preceding page 25. 2. Make sure manual shutoff valve is fully closed. 3. Turn off a
TABLE OF CONTENTS Safety Information and Warnings ... 3 Installati
11. Turn gas control knob counterclockwise to “ON” position. Continue to turn the gas control knob counterclockwise
THERMOSTAT CONTROL OPERATION 1. The thermostat control on this heater differs from standard thermostats. Standard thermostats simply turn the burne
LIGHTING INSTRUCTIONS SIT-MILLIVOLT VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or
REMOTE CONTROL OR WALL THERMOSTAT NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force. 6. Wait (5)
* If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 11. Turn c
MANUAL LIGHTING PROCEDURE 1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper match and a lighter rod. 2.
FLAME CHECK A periodic check of the flames should be made. The pilot flame should always be present when the gas logs are in operation. See Figure
WIRING DIAGRAM NOTE: “If any of the original wire as supplied with the gas appliance must be replaced, it must be replaced with a wire of at least a
WARNING: ELECTRICAL GROUNDING INSTRUCTION: THIS HEATER IS EQUIPPED WITH A THREE-PRONG PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLU
IMPORTANT SAFEGUARDS Although your gas logs are very realistic in appearance, it is not a real burning fireplace and must not be used for burning rej
Page 2
TROUBLE SHOOTING WARNING TURN OFF, UNPLUG HEATER AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR HEATER. C
OBSERVED PROBLEM ODS/PILOT lights but flame goes out when control knob is released 4. Air in gas lines when installed 5. Depleted ga
OBSERVED PROBLEM Burner does not light after ODS/Pilot is lit Delayed ignition of burner Burner backfiring during combustion Slight smo
WARNING IF YOU SMELL GAS: * SHUT OFF GAS SUPPLY * DO NOT TRY TO LIGHT APPLIANCE * DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY
SERVICING Repair and replacement work should only be performed by a qualified service technician. Always shut off the gas supply and make sure heate
REPLACEMENT PARTS ITT VALVE (Picture on page 44) KEY# PART DESCRIPTION PART NUMBER 1. Female Terminals PE 5X42 2. Regulator (LP) Maxitrol
ON123456789201318171516141912111040THERMOGENAUXPRESS TORESETOFFPILOTONITTGENERALCONTROLSPILOTADJ Page 44
REPLACEMENT PARTS SIT MODULATING OR SIT MANUAL (Picture on page 46) KEY# PART DESCRIPTION PART NUMBER 1. Pilot (NAT.) Copreci PE 215005
PILOTOFFHILOSit63141296851251271017131113151644 Page 46
REPLACEMENT PARTS SIT MILLIVOLT VALVE (Picture on Page 48) KEY# PART DESCRIPTION PART NUMBER 1. 82
SECTION I SAFETY INFORMATION WARNINGS IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO A
SIT MILLIVOLT 15 8 16 2 4 5 3 7 1 6 17 18 19 9 10 11 13 12 14 20 21 Page 48
NEW BUCK CORPORATION We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard wr
Page 50
5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure. 6. What To Do IF You Smell Gas: Shu
21. All heater screens must be kept closed when operating the gas logs. 22. ”WARNING: Failure to keep the primary air opening(s) of the burner(s) cl
INSTALLATION FOR MODEL 42 (ZC or WS) Your New Buck Vent-Free Gas Fireplace Heater may be installed in Residential or *After-Market Manufactured Mobil
Fireplace and Framing Dimensions For Model 42 (ZC) Zero Clearance Installation GAS LINE41-1/2"18-15/16"35-5/8"36-5/8"19"2-