New Buck Corporation 42 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Kamine New Buck Corporation 42 herunter. New Buck Corporation 42 User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 52
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
MODEL 42
MAY BE INSTALLED AS A ZERO CLEARANCE FIREPLACE
OR WITH AN OPTIONAL WOODEN SURROUND
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is in-
stalled. Provisions for adequate combustion and ventilation air must be provided. Refer to
section “ Producing Adequate Ventilation” page 13.
This appliance may be installed in an aftermarket, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.
Manufacturer: NEW BUCK CORPORATION
P.O. Box 69
8000 Highway 226 South
Spruce Pine, NC 28777
This appliance is intended for supplemental
heating.
Revised December 2006
VENT-FREE
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Seitenansicht 0
1 2 3 4 5 6 ... 51 52

Inhaltsverzeichnis

Seite 1 - MODEL 42

MODEL 42 MAY BE INSTALLED AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND WARNING: If the information in this manual is not followe

Seite 2

FIREPLACE CLEARANCES (ZC) The fireplace may be placed directly on a combustible floor, against a combustible wall at marked clearances, or on a ra

Seite 3 - TABLE OF CONTENTS

FINISHING YOUR FIREPLACE (ZC) There is a wide variety of finishing material available for your fireplace from formal wall treatments with marble and m

Seite 4

MANTEL PROFILES FOR ZERO CLEARANCE (ZC) CABINET MUST BE FOLLOWED 3"50-3/8"2-3/8"2-3/8"FRONT VIEW OF MODEL 42-ZC-FPFLAT MANTEL WITH

Seite 5 - SECTION I

INSTALLATION OF MODEL 42 (WS) WITH OPTIONAL WOODEN SURROUND (KIT#PAKDM42) 1. When choosing the right location for your heater and wooden surround (m

Seite 6

9. Now you are ready to position the log set. See pages 18, 19, 20. 10. To light the heater, see “Lighting Instructions”, pages 21 through 32. Make

Seite 7

PRODUCING ADEQUATE VENTILATION This section is for residential or manufactured (mobile) installation “This heater shall not be installed in a confine

Seite 8 - GAS LINES

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION DETERMINE IF YOU HAVE A CONFINED OR UNCONFINED SPACE Use this worksheet to determine if you have co

Seite 9 - Zero Clearance Installation

VENTILATION AIR VENTILATION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconfined space. When venting to an adjoining space

Seite 10 - INSTALLING THE FIREBOX (ZC)

VENTILATION AIR FROM OUTDOORS Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12&q

Seite 11 - CLEARANCES (ZC)

WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS. GAS CONNECTION Check gas type. Use only the type of gas indicated on the valv

Seite 13

PLACEMENT OF LOGS FOR FP-42-ZC DX 2733 Open the carton containing the logs. The logs are boxed separated: WARNING: POSITIONING OF LOGS IS VERY

Seite 14

NOTE: When operated for the first time, logs may emit a “paper burning” smell. This smell will gradually diminish and will be totally eliminated af

Seite 15 - VENTILATION

EMBER STOVE LOG SET PLACEMENT FOR MODEL 42 MODEL E.S.B: 1)Rear Log, 2)Middle Log, 3)Left Top Middle Log, 4)Right Top Middle Log 5)Left Fron

Seite 16 - HEATER LOCATION

CR3329 CERAMIC LOG SET PLACEMENT FOR MODEL 42 (1) (2) (4) (3) WARNING: Failure to position the parts in accordance with these diagra

Seite 17 - VENTILATION AIR

LIGHTING INSTRUCTIONS MILLIVOLT VALVE (ITT) FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE O

Seite 18

LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on previous page. 2. Make sure the manual shutoff valve is fully closed. If equipped w

Seite 19 - GAS CONNECTION

• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. TO TURN O

Seite 20 - GAS PRESSURE CHECK

THERMOSTAT CONTROL OPERATION • This valve operates off of millivolts produced by the generator. You may choose to use an optional Wall Thermostat o

Seite 21 - For 19GL Base in Model 42ZC

LIGHTING INSTRUCTION MODULATING VALVE (SIT) OR MANUAL VALVE (SIT) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLO

Seite 22

LIGHTING INSTRUCTION 1. STOP! Read the safety information on preceding page 25. 2. Make sure manual shutoff valve is fully closed. 3. Turn off a

Seite 23

TABLE OF CONTENTS Safety Information and Warnings ... 3 Installati

Seite 24 - WARNING

11. Turn gas control knob counterclockwise to “ON” position. Continue to turn the gas control knob counterclockwise

Seite 25 - LIGHTING INSTRUCTIONS

THERMOSTAT CONTROL OPERATION 1. The thermostat control on this heater differs from standard thermostats. Standard thermostats simply turn the burne

Seite 26 - CAUTION

LIGHTING INSTRUCTIONS SIT-MILLIVOLT VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or

Seite 27 - MANUAL LIGHTING PROCEDURE

REMOTE CONTROL OR WALL THERMOSTAT NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force. 6. Wait (5)

Seite 28 - OR MANUAL VALVE (SIT)

* If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 11. Turn c

Seite 29

MANUAL LIGHTING PROCEDURE 1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper match and a lighter rod. 2.

Seite 30 - TO TURN OFF GAS TO APPLIANCE

FLAME CHECK A periodic check of the flames should be made. The pilot flame should always be present when the gas logs are in operation. See Figure

Seite 31

WIRING DIAGRAM NOTE: “If any of the original wire as supplied with the gas appliance must be replaced, it must be replaced with a wire of at least a

Seite 32 - SIT-MILLIVOLT VALVE

WARNING: ELECTRICAL GROUNDING INSTRUCTION: THIS HEATER IS EQUIPPED WITH A THREE-PRONG PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLU

Seite 33

IMPORTANT SAFEGUARDS Although your gas logs are very realistic in appearance, it is not a real burning fireplace and must not be used for burning rej

Seite 34

Page 2

Seite 35

TROUBLE SHOOTING WARNING TURN OFF, UNPLUG HEATER AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR HEATER. C

Seite 36 - DX 2733 SPLIT LOG SET

OBSERVED PROBLEM ODS/PILOT lights but flame goes out when control knob is released 4. Air in gas lines when installed 5. Depleted ga

Seite 37 - WIRING DIAGRAM

OBSERVED PROBLEM Burner does not light after ODS/Pilot is lit Delayed ignition of burner Burner backfiring during combustion Slight smo

Seite 38

WARNING IF YOU SMELL GAS: * SHUT OFF GAS SUPPLY * DO NOT TRY TO LIGHT APPLIANCE * DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY

Seite 39 - CLEANING

SERVICING Repair and replacement work should only be performed by a qualified service technician. Always shut off the gas supply and make sure heate

Seite 40

REPLACEMENT PARTS ITT VALVE (Picture on page 44) KEY# PART DESCRIPTION PART NUMBER 1. Female Terminals PE 5X42 2. Regulator (LP) Maxitrol

Seite 41

ON123456789201318171516141912111040THERMOGENAUXPRESS TORESETOFFPILOTONITTGENERALCONTROLSPILOTADJ Page 44

Seite 42

REPLACEMENT PARTS SIT MODULATING OR SIT MANUAL (Picture on page 46) KEY# PART DESCRIPTION PART NUMBER 1. Pilot (NAT.) Copreci PE 215005

Seite 43

PILOTOFFHILOSit63141296851251271017131113151644 Page 46

Seite 44 - SERVICING

REPLACEMENT PARTS SIT MILLIVOLT VALVE (Picture on Page 48) KEY# PART DESCRIPTION PART NUMBER 1. 82

Seite 45 - REPLACEMENT PARTS

SECTION I SAFETY INFORMATION WARNINGS IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO A

Seite 46

SIT MILLIVOLT 15 8 16 2 4 5 3 7 1 6 17 18 19 9 10 11 13 12 14 20 21 Page 48

Seite 47

NEW BUCK CORPORATION We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard wr

Seite 48

Page 50

Seite 49

5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure. 6. What To Do IF You Smell Gas: Shu

Seite 50 - SIT MILLIVOLT

21. All heater screens must be kept closed when operating the gas logs. 22. ”WARNING: Failure to keep the primary air opening(s) of the burner(s) cl

Seite 51 - NEW BUCK CORPORATION

INSTALLATION FOR MODEL 42 (ZC or WS) Your New Buck Vent-Free Gas Fireplace Heater may be installed in Residential or *After-Market Manufactured Mobil

Seite 52

Fireplace and Framing Dimensions For Model 42 (ZC) Zero Clearance Installation GAS LINE41-1/2"18-15/16"35-5/8"36-5/8"19"2-

Kommentare zu diesen Handbüchern

Keine Kommentare